50
E65
E65: Thermostat Open
E65
High Vent restriction, High-Limit Thermostat defective or Inlet Thermal Limiter
tripped.
Checks to perform:
WARNING
Check that all the connectors are correctly
inserted.
Check the ventilation of Dryer. Is the ventilation clean?
(See Fig. 1)
Y
E
S
Check Inlet Thermal Limiter for the continuity. Is the
continuity there?
Clean the ventilation and repeat the diagnostic
cycle to check for any further alarms.
Replace Inlet Thermal Limiter and repeat the
diagnostic cycle to check for any further alarms.
NO
NO
Check the working of Exhaust Vent System (there
should not be any air blockage) (See Fig. 2)
Y
E
S
Check High-Limit Thermostat for the continuity. Is the
continuity there?
Remove the air blockage and make Exhaust Vent
System proper and repeat the diagnostic cycle to
check for any further alarms.
Replace High-Limit Thermostat and repeat the
diagnostic cycle to check for any further alarms.
NO
NO
Y
E
S
Y
E
S
Replace the Electronic Control Board and repeat the
diagnostic cycle to check for any further alarms.
Troubleshooting Based on Alarm Codes