EasyManua.ls Logo

Electrolux T5350 - Page 112

Electrolux T5350
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
112
Service Manual
Mismatch between CPU module and Power module internally in Frequency controlled due to bad contact.
Internal message 50.
Recommended actions:
1. Switch off the main power to machine for 5 minutes.
2. Restart the machine.
22:51 DRIVER RELAY
The Motor Control Unit indicates error E.dri.
Error in Driver relay.
Internal message 51.
Recommended actions:
1. Switch off the main power to machine for 5 minutes.
2. Restart the machine.
22:52 HYBRID
The Motor Control Unit indicates error E.Hyb.
Error hybrid. Invalid encoder interface identifier. Not used in this application.
Internal message 52.
22:54 COUNTER OVERRUN 1
The Motor Control Unit indicates error E.co1.
Counter overflow encoder channel 1. Not used in this application
Internal message 54.
22:55 COUNTER OVERRUN 2
The Motor Control Unit indicates error E.co2.
Counter overflow encoder channel 2. Not used in this application
Internal message 55.
22:56 BRAKE
The Motor Control Unit indicates error E.br.
Error brake. Not used in this application.
Internal message 56.
22:57 INITIALISATION MFC
The Motor Control Unit indicates error E.InI.
MFC not booted.
Internal message 57.
22:58 OVER SPEED
ERROR over speed in KEB Motor Control Unit.
Internal message 105.
Recommended actions:
1. Restart the machine.
22:87 OVERHEAT INT.
Warning: The Motor Control Unit indicates A.OHI.
Internal overheating in frequency controller. Can only be reset when internal temperature has dropped by 3 °C.
This is indicated by message A.nOHI. See also error code 22:92.
Internal message 87.
Recommended actions:

Table of Contents