EasyManua.ls Logo

Electrolux T5350 - Page 113

Electrolux T5350
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Service Manual
113
1. Switch off the main power to machine for 30 minutes.
2. Restart the machine.
22:88 NO OVERHEAT POWER MODULE
Warning: The Motor Control Unit indicates A.nOH.
Warning Overtemperature of power module heat sink is reset. See also error code 22:89.
Internal message 88.
Recommended actions:
1. Restart the machine.
22:89 OVERHEAT POWER MODULE
Warning: The Motor Control Unit indicates A.OH.
Overtemperature of power module heatsink. See also error code 22:88.
Internal message 89.
Recommended actions:
1. Switch off the main power to machine for 30 minutes.
2. Restart the machine.
22:90 EXTERNAL FAULT
Warning: The Motor Control Unit indicates A.EF.
External fault. This warning can be triggered if a digital input is programmed as external error input, and trips. Not
used in this application.
Internal message 90.
22:91 NO DRIVE OVERHEAT
Warning: The Motor Control Unit indicates A.ndOH.
Warning Drive motor overheat is reset. See also error code 22:96.
Internal message 91.
Recommended actions:
1. Restart the machine.
22:92 NO OVERHEAT INT.
Warning: The Motor Control Unit indicates A.nOHI.
Overheat internal is reset. See also error code 22:87.
Internal message 92.
Recommended actions:
1. Restart the machine.
22:93 BUS
Warning: The Motor Control Unit indicates A.buS.
Timeout of monitoring time of communication between bus operator and inverter (Watchdog).
Internal message 93.
Recommended actions:
1. Switch off the main power to machine for 5 minutes.
2. Restart the machine.
22:94 PROTECT. ROT. FORWARD
The Motor Control Unit indicates error A.PrF.
Forward (right) limit switch is activated. Not used in this application.
Internal message 94.

Table of Contents

Related product manuals