119
15.3Descriptionoferrorcodesandcauses
MAINCOMMON
10:1INTERNALERRORCPUTACHO
TachoinputonCPUdeliversvaluesthatisoutofrange.
Recommendedactions:
1.Runmotoronhighestpossiblespeedinservicemode.CheckinputvalueforRPMspeed.
2.Replacedefectivecomponent.
10:11REALTIMECLOCKOUTOFORDER
Therealtimeclockisusedbythecontrolsystemfordelayedstart,measuringtime,powerfailure,
errorcodes,etc.
Uponpoweron,thecommunicationwiththeinternalrealtimeclockinthecontrolsystemis
established.Incasethisfails,thiserroroccurs
Recommendedactions:
1.Poweroffthemachinefor1minuteandtryagain.
10:13INITIALIZATIONFAILED
Theerrorcodeisshownifthehardwareinitializationhasfailedtoinitializewithin15seconds
afterpoweron.
Recommendedactions:
1.Pressthecontrolknob/startbuttontoretry.
2.Uploadanewsoftwarethatmatchesthemachinecongurationandtryagain.
10:15MACHINESTOP
ThismessageisshownifinputforMACHINESTOPisactivated.
Thisisnotanerrorcodebutishandledinthesameway.
Recommendedactions:
1.ResettheMachineStopButton.
2.Pressthecontrolknobtoconrmmachinestop.MachinewillreverttoIdlemode.
10:16EMERGENCYSTOP
ThismessageisshownifinputforEMERGENCYSTOPisactivated.Thisisnotanerrorcodebutis
handledinthesameway.
Recommendedactions:
1.ResettheEmergencyStopButton.
2.Pressthecontrolknobtoconrmemergencystop.MachinewillreverttoIdlemode.