Troubleshooting
165
15.3.5EXTERNALCOM.CMIS
50:18STARTNOTALLOWED
ExternalMISsystem(managementinformationsystem)hasdeniedthemachinetostart.MIS
systemcanbeanyexternal,communicatingsystem,likeCMIS,Paymentssystem,TMISetc.
Recommendedactions:
1.Checkforreasoninpaymentsystem.Programnotpaid,T ooshorttimeofbookedsessionleft
fortheselectedprogram,Machinenotreserved,Startnotallowed.
2.Externalinputfor"STARTNOTallowed"isactive.
50:20OUTOFOPERATION
ExternalMISsystem(managementinformationsystem)hassetmachineoutofoperation.
MISsystemcanbeanyexternal,communicatingsystem,likeCMIS,Paymentssystem,TMISetc.
Recommendedactions:
1.CheckforthereasoninthesettingsforMISsystem.