46
Heatingunit,gas
9Heatingunit,gas
9.1Replacementofgasburner
Shutoffthemanualgasvalve.
Disconnectthepowertothemachine.
Demountthetworearpanels.
63
g.7215E
Unscrewthetwoscrewstothebracket(A)holdingthegasvalve.
Disconnecttheheatingsensor(PT100)andtheoverheatprotection(B).
64
g.7272