Troubleshooting
129
12:5OUTLETAIRSENSOR-OPEN
TheerrorcodeisshowniftheanaloginputOUTLETAIRTEMP(NTC)isreadingaresistanceof
morethanapproximately26.7kΩ.ProbablycausedbybrokenNTCsensororwiring.
IftheoutletairtemperatureintheSHOWINPUTSmenushowsatemperatureof-10°Ctheoutletair
sensorisopen.
Whentheoutletairsensorisrestoredtheerrorcodeisautomaticallyresetandtheongoing
programwillcontinue.
Alongpressonthecontrolknob/startbuttonwillmakethecontrolsystemresetandongoing
programwillbeended.
Theerrorcodecanbetriggedif:
Thesensor,harnessorconnectorisbroken.Thesensorshallmeasurearound5KOhminroom
temperature,seetable.(Measuredirectoverthesensor).
IfthemeasureofoutletairisOK,butthereisstillanerrorcode:
Checktheharness,connectorsandfunctionsbyreadingtheelectricalschematicandbyusing
theSHOWINPUTSmenuwhenthemachineisinservicemode.
Temp-Sensorresistance
-10°C-26.7
15°C-7.6
20°C-6.0
25°C-4.8
30°C-3.9
100°C-0.33