136
Troubleshooting
13:8DOORUNLOCKING
Theerrorcodeisshownifunbalanceswitchisactiveatprogramstart.
Recommendedactions:
1.Checkunbalanceswitchforproperalignment..
2.Checkunbalanceswitchforelectricalfault.
13:9WATERINDRUM-CALLSERVICE
Thiserrorcodewillbeshownifthecontrolsystemdetectswaterabovesafetylevelwhenprogram
isnished.Possiblycausedbybrokeninletvalveand/ordrainvalve.
Recommendedactions:
1.Turnoffwaterinlettomachine.
2.Manuallyopenthedrainvalve.
3.Checkreasonforvalvemalfunction.
13:10WATERINDRUM-CALLSERVICE
Thiserrorcodewillbeshownifthecontrolsystemdetectswaterabovesafetylevelinidlemode.
Possiblycausedbybrokeninletvalveand/ordrainvalve.
Recommendedactions:
1.Turnoffwaterinlettomachine.
2.Manuallyopenthedrainvalve.
3.Checkreasonforvalvemalfunction.
13:11UNLOADINGDOORNOTLOCKED
ThiserrorcodewillbeshownifthecontrolsystemdetectsthattheinputDOORLOCKED2hasnot
beenactivatedwithinacertaintimeafterunloadingdoorisclosed.
ItwillalsobeactivatediftheinputDOORLOCKED2hasbeendeactivatedduringanon-going
program.
Possiblecauses:
Thiscanbecausedbyamechanicalproblempreventingdoorlocktolock,defectivedoorlock,
loosecableconnectiontodoorlock,brokencablestodoorlockormechanicalproblemwith
emergencyopeningofthedoor.
Recommendedactions:
1.Checkdoorlockfunctionalityinserviceprogram,byactivatingdoorlockandthenbychecking
checkinputs.
2.Checkelectricalconnectionsbyreadinginputsatthesametimeascablescarefully
moved/pulled.
3.Carefullyknockonthedoorlockunittolocateintermittenterrors.