EasyManua.ls Logo

Electrolux T5675 - Page 145

Electrolux T5675
174 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Troubleshooting
145
21:7LOWDCVOLTAGE
ThiserrorcodeisgeneratedbytheMCUfordrummotor.
TheMCUconstantlymeasuresthevoltageoverthemainsinput.Ifthevoltageisbelowapredened
limit,theMCUwillshutoffthecurrenttothemotor.Oncethemotorhasstopped(=thetachosensor
indicatesthatthemotorisstationary),theMCUcheckstoseewhethertheinputvoltageisstilllow.
Ifitis,thiserrorcodeisshown.Thereasonforthiserrorcodebeingactivatedcanbelowmains
voltageorthatthemachine’son/offswitchhasbeenoperatedinanunsuitablemanner.
FurtherinformationcanbeobtainedbystudyingthecontentsofMCUERRORLOG1andMCU
ERRORLOG2:
UNDERVOLTAGE2(specieshowmanytimesthiserrorcodehasbeenactive).
UNDERVOLTAGE1(specieshowmanytimesthevoltagehasdroppedbelowthelimit.The
differencebetweenundervoltage1andundervoltage2indicateshowmanytimestherehasbeen
anundervoltage1withoutitbeingconrmedwhenthemotorhasstopped).
LASTFAULTCODEN/8(showsthe8latesterrorcodes)Undervoltagescanberegistered
evenduringnormaloperation.Consequently,asmallnumberofregistrationsneednotmean
thatthereisanerrorintheMCU.
Recommendedactions:
1.Checkthatthesupplyvoltageisstableandneverdropsbelownominalvoltage-10%.
2.Checkthefusesandcables.
3.CheckthesupplyvoltageinthenetworkcablingandattheMCUinthemachine.
21:8HIGHDCVOLTAGE
ThiserrorcodeisgeneratedbytheMCUfordrummotor.
TheMCUconstantlymeasuresthevoltageoverthemainsinput.Ifthevoltageexceedsapredened
limit,theMCUwillshutoffthecurrenttothemotor.Oncethemotorhasstopped(=thetacho
sensorindicatesthatthemotorisstationary),theMCUcheckstoseewhethertheinputvoltage
isstillhigh.Ifitis,thiserrorcodeisshown.
Possiblecauses:
Thereasonforthiserrorcodebeingactivatedcanbehighmainsvoltage(e.g.powersurge).
FurtherinformationcanbeobtainedbystudyingthecontentsofMCUERRORLOG1andMCU
ERRORLOG2:
OVERVOLTAGE2(specieshowmanytimesthiserrorcodehasbeenactive)
OVERVOLTAGE1(specieshowmanytimesthevoltagelimithasbeenexceeded.Thedifference
betweenovervoltage1andovervoltage2givesthenumberoftimesovervoltage1hasoccurred
withoutitbeingconrmedwhenthemotorhasstopped).
LASTFAULTCODEN/8(showsthe8latesterrorcodes).Overvoltageregistrationscanalso
occurifthereisabadcontactinthetachosignal.Checkalsothefollowingregisters:TACHO
ERRORLOWSPEED(numberofshorttachointerruptionsduringwashrpm).TACHOERROR
HIGHSPEED(numberofshorttachointerruptionsduringextractionrpm).
Recommendedactions:
1.CheckthetachocablesiftherearemanyregistrationsintheTACHOCUT-OUTregisters.

Table of Contents

Other manuals for Electrolux T5675

Related product manuals