Troubleshooting
157
22:99OVERLOAD1
Warning:TheMotorControlUnitindicatesA.OL.
Overloadcounterhasreached100%.
Thewarningcanonlyberesetafteroverloadcounterhasreached0%again.Thisisindicatedby
themessageA.nOL.Seealsomessage22:98.
Internalmessage99.
Leavemachinepoweredupwithoutrunninganyprogramfor30minutes.
Recommendedactions:
1.Checkmachineisnotloadedmorethanintended.
2.Checkmotoranddrumformechanicalfault.(jamming).
3.Checkmotorforelectricalfault.
4.Restartthemachine.
22:100OVERLOAD2
Warning:TheMotorControlUnitindicatesA.OL2.
Standstillconstantcurrentexceeded.
Themessagecanonlyberesetaftercoolingtimehaselapsed.Thisisindicatedbythemessage
A.nOL2.Seealsomessage22:101.
Internalmessage100.
Recommendedactions:
1.Waituntilmessage22:101,NOOVERLOAD2isshown.
2.Restartthemachine.
22:101NOOVERLOAD2
Warning:TheMotorControlUnitindicatesA.nOL2.
Coolingtimehaselapsed,erroroverload2isreset.Seealsomessage22:100.
Internalmessage101.
Recommendedactions:
1.Restartthemachine.
22:102SET
Warning:TheMotorControlUnitindicateserrorA.SEt.
Ithasbeenattemptedtoaccessalockedparameterset.
Internalmessage102.
Recommendedactions:
1.Upgrademachinesoftwaretolatestversion.
2.Restartthemachine.