ELIS PLZEŇ a. s., Luční 425/15, 301 00 Plzeň, Czech Republic, Phone: +420/377 517 711, Fax: +420/377 517 722 Es90420K/c
4.1.7. Dimensions of flangeless sensor
* Dimension A (sensor height) is without transmitter housing (or terminal box).
The sensor weight is an indicative value.
Caution: Connection for counter flanges ASME (ANSI) for flangeless version is supplied starting with NPS 1"
to NPS 8".
(Sensors are one dimension smaller due the installation between flanges from NPS 1" up to NPS 3"; for
example: request from customer NPS 1" means sensor with internal diameter NPS 3/4", and it corresponds
with a range of flow rates).
From NPS 4" to NPS 8" sensors are of the same diameters.
Note: The grounding rings for a flangeless version: size of the grounding rings should be the same size as a
size of the existing pipe - valid for EN 1092-1 and ASME (ANSI) standards.