62 100-412-196 REV. 06
3
Use the Up/Down Arrow keys and the Left/Right Arrow keys
to select Continuous Mode, then press the Enter key to
confirm the selection. You will be directed to the parameters
area.
4
Amplitude icon will flash. Press the Enter key to change
parameters.
Amplitude parameters numbers will flash. Use the Up/Down
Arrow keys and the Left/Right Arrow keys to enter the
desired value, then press the Enter key to confirm the
selected value.
NOTICE
Only the parameters associated with the selected mode will
be displayed.
NOTICE
Reference image showing default Amplitude setting of 50%.
5
Ground Detect icon will flash. Press the Enter key to change
the parameters.
Ground Detect parameter numbers will flash. Use the Up/
Down Arrow keys and the Left/Right Arrow keys to enter the
desired value, then press the Enter key to confirm the
selected value.
NOTICE
These parameters will only be visible if the unit has the
optional Ground Detect feature installed.
NOTICE
Reference image showing default Off Time setting of
0.05 sec.
Table 6.9 Continuous Mode Operational Sequence
Step Action Reference