24 Installation
Figure 2-17: Inline Mounting Kit
1
Pipe mounting bracket
2
U-bolt 2 ½ inch diam. pipe (5/16-18 x 3.75 long)
3
5/16 flat lock washer (2)
4
5/16-18 300 series hex nut (2) - Apply Loctite 222 Low Strength Purple Threadlocker to
threads. Torque nuts to 30 in-lbs (3.4 N m)
5
U-bolt clamp assembly - Apply Loctite 222 threadlocker to threads. Torque nuts to 30 in-lbs
(3.4 N m)
2.7.5 Rotating the Housing
To improve accessibility to the HMI module or to ease wiring, you can optionally rotate the
housing.
Important
Never rotate the housing from its original (as-shipped) position. Over-rotation can break electronics
within the unit.