Do you have a question about the Emerson VERDANT VX Series and is the answer not in the manual?
Wi-Fi Connectivity | Yes |
---|---|
Wi-Fi Capable | Yes |
Color Options | White |
Compatibility | Most HVAC systems |
Mobile App | Yes |
Connectivity | Wi-Fi |
Identifies and describes the components included in the shipment.
Instructions for connecting the wireless antenna module to the server.
Instructions for connecting the server to the LAN port using an RJ-45 cable.
Steps to connect the server to an electrical outlet using the supplied power cord.
Steps to ensure the online connection kit receives a static IP address and is properly whitelisted.
Guidance on selecting a location and mounting the thermostat securely to the wall.
Instructions for selecting a location and mounting the external occupancy sensor.
Steps for plugging in the wireless sensor receiver and mounting the sensor.
Details on how to fish and connect the wire from the occupancy sensor to the thermostat.
Overview of steps to correctly configure the thermostat for HVAC unit operation.
Procedure to access the thermostat's configuration settings by pressing the config button.
Instructions on how to enter the room number using the thermostat's interface.
Guide to entering the equipment code based on HVAC unit type using the thermostat interface.
Steps to select an energy saving preset from E-0 to E-5 using the thermostat interface.
Instructions for setting the thermostat's clock to the current time in 24-hour format.
How to test if the thermostat is correctly controlling the HVAC unit's heating, cooling, and fan.
How to access custom energy savings settings by pressing and holding the Configuration button.
General instructions on navigating and changing settings using the thermostat's buttons.
Setting for manual or automatic fan control modes on the thermostat.
Setting the temperature difference for initiating 1st stage heating.
Setting the temperature difference for initiating 2nd stage heating.
Setting the temperature difference for initiating 1st stage cooling.
Setting the minimum time for occupancy detection to enter guest occupancy mode.
Setting the minimum time for occupancy detection during night to consider the room occupied.
Setting the duration for 1st stage heating before 2nd stage heating is initiated.
Setting the start time for the Night Occupancy mode in 24-hour format.
Setting the end time for the Night Occupancy mode in 24-hour format.
Setting the maximum time allowed for the PTAC unit to attain the recovery temperature.
Setting the target room temperature for heating recovery.
Setting the time delay before temperature setback is initiated in heat mode.
Setting the minimum temperature when the room is unoccupied and in setback mode.
Setting the time delay before temperature setback is initiated in cool mode.
Setting the maximum temperature when the room is unoccupied and in setback mode.
Setting the target room temperature for cooling recovery.
Setting the minimum temperature a guest can select.
Setting the maximum temperature a guest can select.
Selecting between manual or automatic temperature control modes.
Setting the difference between set points for automatic heating/cooling mode changes.
Configuring setback points and auto-restore behavior for guest settings.
Enabling or disabling automatic humidity control features.
Calibrating the temperature display on the thermostat.
Steps to access the sensor configuration screen on the thermostat.
Instructions on configuring the thermostat for use with a wired auxiliary occupancy sensor.
How to switch the lighting signal between Normally Open and Normally Closed configurations.
Lists common error codes displayed by the thermostat and their meanings.
Procedure for pairing the thermostat with a Network Programmer before installation.
Steps to reset the thermostat to its default parameters to resolve issues.