Product description Deltabar PMD78B PROFINET with Ethernet-APL
12 Endress+Hauser
Applications for diaphragm seals
Diaphragm seal systems are used if the process and the device need to be separated.
Diaphragm seal systems offer clear advantages in the following instances:
In the case of extreme process temperatures - through the use of temperature isolators
or capillaries
In the case of strong vibrations - decouple the process from the device by using a
capillary
In the case of aggressive or corrosive media - through the use of high-durability
membrane materials
In the case of media that crystallize or contain solids - through the choice of suitable
coatings
In the case of heterogeneous and fibrous process media
If extreme measuring point cleaning is necessary, or in the event of very damp mounting
locations
For mounting locations that are difficult to access
3.1.2 Level measurement (volume and mass):
Diaphragm seal with temperature isolator on both sides
h =
p
ρ g
+ -
+
h
A0038339
h Height (level)
Δp Differential pressure
ρ Density of the medium
g Gravitational acceleration
Diaphragm seal on both sides with capillary
+ -
+
h =
p
ρ g
h
A0038345
h Height (level)
Δp Differential pressure
ρ Density of the medium
g Gravitational acceleration