Micropilot FMR56, FMR57
Endress+Hauser 25
Device plugs
In device versions with a device plug (M12 or 7/8"), it is not necessary to open the housing in
order to connect the signal cable.
2
1
34
A0011175
 16 Pin assignment of M12 plug
1 Signal +
2 Not assigned
3 Signal –
4 Ground
4
2
3
1
A0011176
 17 Pin assignment of 7/8" plug
1 Signal –
2 Signal +
3 Not assigned
4 Shielding