Proline Promass P 300
102 Endress+Hauser
Ex db eb
Category Type of protection
II1/2G Ex db eb ia IIC T6…T1 Ga/Gb
Ex db eb ia IIB T6…T1 Ga/Gb
II2G Ex db eb ia IIC T6…T1 Gb
Ex db eb ia IIB T6…T1 Gb
Ex db
Category Type of protection
II1/2G Ex db ia IIC T6…T1 Ga/Gb
Ex db ia IIB T6…T1 Ga/Gb
II2G Ex db ia IIC T6…T1 Gb
Ex db ia IIB T6…T1 Gb
Ex ec
Category Type of protection
II3G Ex ec IIC T5…T1 Gc
Ex tb
Category Type of protection
II2D Ex tb IIIC T** °C Db
C
CSA
US
Currently, the following versions for use in hazardous areas are available:
IS (Ex i) and XP (Ex d)
Class I, III, III Division 1 Groups A-G
Class I, III, III Division 1 Groups C-G
NI (Ex nA)
Class I Division 2 Groups A - D
Ex de
Class I, Zone 1 AEx/ Ex de ia IIC T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex de ia IIB T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex de ia IIC T6…T1 Gb
Class I, Zone 1 AEx/ Ex de ia IIB T6…T1 Gb
Ex d
Class I, Zone 1 AEx/ Ex d ia IIC T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex d ia IIB T6…T1 Ga/Gb
Class I, Zone 1 AEx/ Ex d ia IIC T6…T1 Gb
Class I, Zone 1 AEx/ Ex d ia IIB T6…T1 Gb
Ex nA
Class I, Zone 2 AEx/ Ex nA IIC T5...T1 Gc
Ex tb
Zone 21 AEx/ Ex tb IIIC T** °C Db