EasyManua.ls Logo

Endress+Hauser Proline Promass P 300 - Operability; Operating Concept

Endress+Hauser Proline Promass P 300
112 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promass P 300
Endress+Hauser 89
Process connections
Fixed flange connections:
EN 1092-1 (DIN 2501) flange
EN 1092-1 (DIN 2512N) flange
ASME B16.5 flange
JIS B2220 flange
DIN 11864-2 Form A flange, DIN 11866 series A, flange with notch
BBS flange small (sterile orbital), DIN 11866 series A, female
BBS flange small (sterile orbital), DIN 11866 series B, female
Clamp connections:
Tri-Clamp (OD tubes), DIN 11866 series C
DIN 11864-3 Form A clamp, DIN 11866 series A, with notch
DIN 32676 clamp, DIN 11866 series A
ISO 2852 clamp, ISO 2037
ISO 2852 clamp, DIN 11866 series B
BBS Quick-Connect (sterile orbital), DIN 11866 series A, female
BBS Quick-Connect (sterile orbital), DIN 11866 series B, female
Neumo BioConnect clamp, DIN 11866 series A, clamp form R
Eccentric clamp connection:
Eccen. Tri-Clamp, DIN 11866 series C
DIN 11864-3 Form A clamp, DIN 11866 series A, with notch
DIN 32676 clamp, DIN 11866 series A
ISO 2852 clamp, DIN 11866 series B
BBS Quick-Connect (sterile orbital), DIN 11866 series A, female
BBS Quick-Connect (sterile orbital), DIN 11866 series B, female
Neumo BioConnect clamp, DIN 11866 series A, clamp form R
Thread:
DIN 11851 thread, DIN 11866 series A
SMS 1145 thread
ISO 2853 thread, ISO 2037
DIN 11864-1 Form A thread, DIN 11866 series A
BBS thread (sterile orbital), DIN 11866 series A
BBS thread (sterile orbital), DIN 11866 series B
Process connection materials →  88
Surface roughness
All data relate to parts in contact with fluid. The following surface roughness quality can be ordered.
Ra
max
= 0.76 µm (30 µin)
Ra
max
= 0.38 µm (15 µin) electropolished
Delta ferrite <1%
Operability
Operating concept
Operator-oriented menu structure for user-specific tasks
Commissioning
Operation
Diagnostics
Expert level
Fast and safe commissioning
Guided menus ("Make-it-run" wizards) for applications
Menu guidance with brief descriptions of the individual parameter functions
Device access via Web server or SmartBlue app →  109
WLAN access to the device via mobile handheld terminal, tablet or smart phone
Reliable operation
Operation in local language →  90
Uniform operating philosophy applied to device and operating tools
If replacing electronic modules, transfer the device configuration via the integrated memory
(HistoROM backup) which contains the process and measuring device data and the event logbook.
No need to reconfigure.

Table of Contents

Related product manuals