Endress+Hauser 29
Power consumption Transmitter
Max. 10 W (active power)
switch-on current Max. 36 A (as per NAMUR Recommendation NE21)
Current consumption Transmitter
Max. 400 mA (24 V)
Max. 200 mA (110 V, 50/60 Hz; 230 V, 50/60 Hz)
Power supply failure
Totalizers stop at the last value measured.
Depending on the device version, the configuration is retained in the device memoryor in the
pluggable data memory (HistoROM DAT).
Error messages (incl. total operated hours) are stored.