Soliwave FQR56/FDR56
Installation
Endress+Hauser 15
An improvement of signal quality can be attained by installing the FQR56 transmitter and
FDR56 transceiver so that they can be moved along their longitudinal axis.
D-D ( 1 : 10 )
E-E ( 1 : 10 )
D
D
E
E
FQR56
FDR56
A
A
5 Improvementofsignalquality
A Movementof±10mm
Installationproceduretoimprovethesignalqualityonfreeorminimumcoveredpathaeran
executed setup:
Move device 1 (example FDR56) to increase the maximum possible signal strength
displayed on the FDR56.
(Example:
→ )
Then move device 2 (example FQR56) to increase the maximum possible signal strength
on the FDR56 again.
(Example:
→ )
Followinganyrepositioningofthedevices(horizontalinthiscase),anewsetupshouldbe
performed(→34).