S o n o m a U s e r M a n u a l
70
C H A P T E R N I N E
71
S o n o m a U s e r M a n u a l
C O N T R O L A N D S T A T U S C O M M A N D S
lockoutkp Command to lock out access to the front-panel keypad EDIT
key. See the kplockstat and unlockkp commands.
netcong Interactive script that allows you to congure the IP network
subsystem of the Sonoma.
ntpcong Interactive script that guides you in conguring the NTP
Subsystem. Allows conguration of MD5 authentication and
broadcast/multicast mode. All parameters are retained in non-
volatile FLASH disk storage.
ntpstat Prints the values of several key parameters indicating the status
of the NTP daemon. These include the current offset between
the NTP-steered system clock and the CDMA Subsystem
clock, and the current counts of received packets, sent packets
and dropped packets. In addition the current sent packet rate is
shown.
oscctrlstat Prints the system oscillator disciplining parameters.
passwd Used to change the password for the user that you are logged
in as.
ptpcong0
ptpcong1
(optional)
Interactive script that guides you in conguring parameters for
the optional PTP/IEEE-1588 protocol. See Chapter 4 - PTP/
IEEE-1588 for more information.
ptpstat0
ptpstat1
(optional)
Prints the status of the optional PTP/IEEE-1588 Subsystem.
See Chapter 4 - PTP/IEEE-1588 for more information.
pwrtmask
(optional)
Prints the current settings of the optional Dual Power Supply
Input Fault Alarm Masks. See Chapter 10 - Options, Masking
Dual Power Supply Fault Alarms for more information.
rcvrversion Prints the CDMA Receiver rmware and FPGA version infor-
mation.
serialnumber Prints the serial number of the Sonoma. The serial number
is not available using this command for units shipped before
August 2015.
setcaldelay An interactive utility that allows you to change the clock cali-
bration delay. See the caldelay command.
setcdmachannelset Command that allows the user to select the channelset for the
CDMA Subsystem to receive. This command is not functional
in units comgured for Japanese Cellular operation.
See the cdmachannelset command.
setpwrtmask
(optional)
Command to enable or mask the optional Dual Power Supply
Input Faults. See Chapter 10 - Options, Masking Dual Power
Supply Fault Alarms for more information.
setsigtmask Command to enable or mask the Signal Loss Fault.
See the sigfltmask command.
sigtmask Prints the current setting for the Signal Loss Fault mask.
See the setsigfltmask command.
subsysreset Command that performs a CDMA Subsystem reset.