Heat Pump Systems
You must enter an Installer Password to access the EQUIPMENT SETTINGS from the Main Menu.
The following settings can be changed for Heat Pump Systems:
Minimum cycle time for the heat pump/auxiliary heater.
Allows the Heat Pump and
Auxiliary Heat to be on at the
same time.
Does not allow Heat Pump and
Auxiliary Heat to be on at the same
time (add-on configuration).
The High Balance Point defines the outdoor temperature above which
the Auxiliary Heater is disabled.
The Low Balance Point defines the outdoor temperature below which
the Heat Pump compressor is disabled.
An outdoor temperature sensor must be installed for the Balance
Points to operate.
WARNING: Check with the manufacturer of your heat pump before reducing the minimum on/off
time below the 3 minute default. The minimum on/off timer is for the protection of the heat pump.