36
Enertech Global IOM, XT Models
Section 8: Electrical Connections
sheet of
dwg #:
old #
DESCRIPTION
ENERTECH
GLOBAL, LLC
2506 S. ELM ST. GREENVILLE, IL 62246
designer
dist greenville mitchell
REQ
break all sharp
machined corners
.015 radius remove
all burs
name:
date:
s
ca
l e t h
is
dr aw
i
n
g
do no
t
ADAM STERNE
fabr. purch. supp.
PART #
PART NAME SPECIFICATION
DIA. THICK WIDTH LENGTH WEIGHT
designer
ENGINEERING DEPARTMENT HEAD
STOCK SIZE:
Parts List
QTYDESCRIPTIONPART NUMBERITEM
1
BOX, CONTROL PLATE, GALVANIZED
13P005−01HN1
1
BOX, CONTROL DIVIDER, GALVANIZED
13P00401HN
2
1
PLATE, TERMINAL STRIP, CONTROL BOX, GALVANIZED
13P003−01HN3
1
75VA TRANSFORMER, 460V PRIMARY−24V SECONDARY
45P001−01NN4
1
LOCKOUT BOARD ROLBIT
114700010015
1
ECM BOARD114700020016
4
BAR, GROUND11420006001
7
4
CLOSED BUSHING, 7/8"114900010018
10
CLOSED BUSHING, 1"114900010029
10
#6 PHILLIPS SCREW 0.50 (
NOT ILLUSTRATED)
11210004002
10
7
5/16 HEX HEAD BLUNT TIP SCREW− 0.38 (NOT ILLUSTRATED)
21P005−01ZZ
11
4
5/16 HEX HEAD BLUNT TIP SCREW, GREEN0.50 (NOT ILLUSTRATED)
1121000500712
1
WIRING HARNESS, SAFETY & CONTROLS, CONTROL BOX, XT & CT
SERIES (NOT ILLUSTRATED)
41P00102NN
13
4
CLIP, WIRE (NOT ILLUSTRATED)
1149000000114
1240 VOLT, HIGH VOLTAGE, ULTRA TEC, COMPRESSOR WIRING
HARNESS, CONTROL BOX, XT & CT REV. C SERIES (NOT ILLUSTRATED)
41P03002NN15
1
WIRING HARNESSTERMINAL STRIP (#1)−THERMOSTAT, XT & CT
SERIES (NOT ILLUSTRATED)
41P00501NN16
1
WIRING HARNESSTERMINAL STRIP
(#2) ACCESSORIES, XT & CT
SERIES (NOT ILLUSTRATED)
41P006−01NN17
1
LOCKOUT BOARD WIRING HARNESS, XT & CT SERIES (NOT
ILLUSTRATED)
41P007−01NN
18
1ECM HIGH VOLTAGE WIRE HARNESS, CONTROL BOX, XT & CT SERIES
(NOT ILLUSTRATED)
41P01002NN19
1
ECM LOW VOLTAGE WIRING HARNESS, CONTROL BOX, XT & CT
SERIES (NOT ILLUSTRATED)
41P01302NN20
1
WIRING HARNESSELECTRIC HEAT, XT & CT SERIES (NOT
ILLUSTRATED)
41P01101NN21
8
TIE, WHITE 6 IN (NOT ILLUSTRATED)
04T00622
5
WASHER, #8 EXT. TOOTH (NOT ILLUSTRATED)
06W00222
1
3 POLE CONTACTOR26C00823
FRONT VIEW
NOTES:
1. WIRING HARNESS: 41P00501NN AND 41P006−01NN
INCLUDE TERMINAL STRIP: 11420002004 (8 PIN PANEL MOUNT)
11420001004 (8 PIN MALE CONNEC TOR)
2. LABELS ARE REFERENCED FROM LABEL SHEET
(P/N: 27P015−03NN).
3. ALL BUSHINGS NEED TO BE PLACED ON THE CONTROL BOX PLATE
BEFORE OTHER ELECTRICAL ITEMS.
8
6
3
5
8
22
9
9
9
21
9
NOT E :
NEED TO KEEP THIS GROUNDING LUG
OPEN FOR FIELD GROUNDING CONDUCTOR!
9
(LABEL 1A)
(LABEL 2B)
BOX, CONTROL PLATE
ASM, DUAL STG., ECM,
460V, 3PH, 60Hz,
COMMERCIAL
13S04001NN
2 2
X
13S040−01NN
CONTROL PLATE
ASM
SEE NOTES
KARA W.
2212
BRYAN L.
13S04001NN
*SEE NOTE 1
*SEE NOTE 1
L1
L2
L3
N
Power
Source
sheet of
dwg #:
old #
DESCRIPTION
ENERTECH
GLOBAL, LLC
2506 S. ELM ST. GREENVILLE, IL 62246
designer
dist greenville mitchell
REQ
break all sharp
machined corners
.015 radius remove
all burs
name:
date:
s
ca
l e t h
is
dr aw
i
n
g
do no
t
ADAM STERNE
fabr. purch. supp.
PART #
PART NAME SPECIFICATION
DIA. THICK WIDTH LENGTH WEIGHT
designer
ENGINEERING DEPARTMENT HEAD
STOCK SIZE:
Parts List
QTYDESCRIPTIONPART NUMBERITEM
1
BOX, CONTROL PLATE, GALVANIZED
13P005−01HN1
1
BOX, CONTROL DIVIDER, GALVANIZED
13P00401HN
2
1
PLATE, TERMINAL STRIP, CONTROL BOX, GALVANIZED
13P003−01HN3
1
TRANSFORMER, 75VA,208/230 w/Bkr
114500000014
1
LOCKOUT BOARD ROLBIT
114700010015
1
ECM BOARD114700020016
1
2 POLE CONTACTOR
114300010017
3
BAR, GROUND114200060018
4
CLOSED BUSHING, 7/8"114900010019
10
CLOSED BUSHING, 1"11490001002
10
10
#6 PHILLIPS SCREW 0.50 (NOT ILLUSTRATED)
11210004002
11
7
5/16 HEX HEAD BLUNT TIP SCREW− 0.38 (NOT ILLUSTRATED)
21P005−01ZZ12
3
5/16 HEX HEAD BLUNT TIP SCREW, GREEN0.50 (NOT ILLUSTRATED)
11210005007
13
1
WIRING HARNESS, SAFETY & CONTROLS, CONTROL BOX, XT & CT
SERIES (NOT ILLUSTRATED)
41P00102NN
14
4
CLIP, WIRE (NOT ILLUSTRATED)
1149000000115
1240 VOLT, HIGH VOLTAGE, ULTRA TEC, COMPRESSOR WIRING
HARNESS, CONTROL BOX, XT & CT REV. C SERIES (NOT ILLUSTRATED)
41P03002NN16
1
WIRING HARNESSTERMINAL STRIP (#1)−THERMOSTAT, XT & CT
SERIES (NOT ILLUSTRATED)
41P00501NN17
1
WIR
ING HARNESSTERMINAL STRIP (#2) ACCESSORIES, XT & CT
SERIES (NOT ILLUSTRATED)
41P006−01NN18
1
LOCKOUT BOARD WIRING HARNESS, XT & CT SERIES (NOT
ILLUSTRATED)
41P007−01NN
19
1ECM HIGH VOLTAGE WIRE HARNESS, CONTROL BOX, XT & CT SERIES
(NOT ILLUSTRATED)
41P01002NN20
1
WIRING HARNESS ELECTRIC HEAT, XT & CT SERIES (NOT
ILLUSTRATED)
41P01101NN21
1
ECM LOW VOLTAGE WIRING HARNESS, CONTROL BOX, XT & CT
SERIES (NOT ILLUSTRATED)
41P01302NN22
8
TIE, WHITE 6 IN (NOT ILLUSTRATED)
04T00623
4
WASHER, #8 EXT. TOOTH (NOT ILLUSTRATED)
06W00224
BRYAN L.
91511
KARA W.
X
2 2
13S03401NN
BOX, CONTROL PLATE
ASSEMBLY, DUAL STG.,
ECM, 208/230V, 1 PH, 60Hz,
COMMERCIALREV.C
SEE NOTES
CONTROL PLATE
ASM
13S034−01NN
13S034−01NN
NOTES:
1. WIRING HARNESS: 41P00501NN AND 41P006−01NN
INCLUDE TERMINAL STRIP: 11420002004 (8 PIN PANEL MOUNT)
11420001004 (8 PIN MALE CONNEC TOR)
2. LABEL NUMBERS ARE REFERENCED FROM LABEL
SHEET (P/N: 27P01503NN).
3. ALL BUSHINGS NEED TO BE PLACED ON THE CONTROL BOX PLATE
BEFORE OTHER ELECTRICAL ITEMS.
9
6
3
5
9
10
10
10
10
NOT E :
NEED TO KEEP THIS GROUNDING LUG
OPEN FOR FIELD GROUNDING CONDUCTOR!
10
(LABEL 1A)
(LABEL 2B)
L1
L2
Power
Source
High Voltage Single Phase Control Box Connections
High Voltage Three Phase Control Box Connections
Top View
Control Box
Air Coil
Side
High Voltage
Wiring Inputs for
Auxiliary Heater
Auxiliary Heater High Voltage Wiring Entry Locations
Refer to Heater Installation and Operations Manual
(20D156-01NN) for installation details

Table of Contents