Installation & Operations Manual
AV MODELS OUTDOOR AIR-TO-WATER HEAT PUMPS
MD/ME MODELS INDOOR MODULE
20D826-01NN
20D826-01NN
A New Era with Advantage...
Enertech’s Advantage system was painstakingly engineered to funcon awlessly between space condioning and
domesc hot water. Our indoor module has truly set the bar with the rst turnkey total comfort soluon. With its
integrated electric or dual fuel opon, each backing up heang and DHW, you’ll never be le out in the cold!
No More Buer Tanks, Free Up Floor Space
Massive Labor & Accessories $avings
Integrated Pumping & Controls
Onboard Emergency Backup

Table of Contents

Questions and Answers

  • A
    Anthony PittsAug 11, 2025
    What to do if Enertech AV Heat Pump has low hot water temperature?
    • K
      Kelsey RodriguezAug 12, 2025
      If you experience low hot water temperature with your Enertech Heat Pump, it may be due to large hot water consumption. In this case, wait until the hot water has heated up. Also, check whether alarm “high condenser out” (162) is displayed, and if so, inspect and clean the strainer.
  • P
    pandradeAug 18, 2025
    Why is Enertech Heat Pump producing low room temperature in heating?
    • J
      Joseph FergusonAug 18, 2025
      If your Enertech Heat Pump is producing low room temperature during heating, it could be due to several reasons. First, check if thermostats are off in several rooms and set them to max in as many rooms as possible. Also, check whether alarm “high condenser in” (163) or “high condenser out” (162) are displayed. If so, follow the instructions for adjusting flow rate.
  • A
    Alex CoxAug 27, 2025
    What to do if there is ice build-up in Enertech AV Heat Pump?
    • P
      paula90Aug 27, 2025
      If you notice ice build-up in the fan, grille, or fan cone on the outdoor module of your Enertech Heat Pump, the de-icing fan may not be activated. To resolve this, activate the “de-icing fan” in menu 5.11.1.1.
  • T
    Timothy ChangSep 3, 2025
    What to do if EAV is not in operation in Enertech AV?
    • T
      Tanya RussoSep 3, 2025
      If the EAV (Electronic Expansion Valve) is not in operation in your Enertech Heat Pump, ensure that the EAV is connected to the power source and that compressor operation is required. Also, check that the addressing of EAV is correct and that the communication cable has been connected.