Enertech Global, LLC 25
AV : MD/ME - Rev. A Models
Installaon and Operaons Manual
To Fan Coil
To Radiant Manifold 1
To Radiant Manifold 2
To Radiant Manifold 3
From
Indoor
Module
From Fan Coil
From Radiant Manifold 1
From Radiant Manifold 2
From Radiant Manifold 3
To
Indoor
Module
This por�on
of the piping/
valves located
in mechanical
room
“HOME RUN” STYLE PIPING
Fan Coil
From Indoor
Module
To Indoor
Module
This por�on
of the piping/
valves located
in mechanical
room
“BRANCH” STYLE PIPING
Branch 1
Branch 4
To Radiant
Floor Loops
Branch 2
Branch 3
From Radiant
Floor Loops
Branch 3
Branch 4
Branch 2
Branch 1

WARNING: WATER TEMPRATURES ABOVE 120 DEG F CAN CAUSE SEVERE
PHYSICAL INJURY IN THE FORM OF SCALDING OR BURNS. AN ANTI-SCALD
VALVE MUST BE INSTALLED AT THE HOT WATER TANK OUTLET WITH THE
VALVE SETTING PROPERLY ADJUSTED TO PREVENT SCALDING OR BURNS.
Figure 12e: An-Scald Valve Piping Connecons
Hot Water Tank
HOT COLD
An-Scald Valve
Cold Water Inlet
Tempered Water
to Faucets/Fixtures

WARNING
WATER TEMPERATURES ABOVE 120° F
CAN CAUSE SEVERE PHYSICAL INJURY
IN THE FORM OF SCALDING OR
BURNS. AN ANTI-SCALD VALVE MUST
BE INSTALLED AT THE HOT WATER
TANK OUTLET WITH THE VALVE
SETTING PROPERLY ADJUSTED TO
PREVENT SCALDING OR BURNS.