Enertech Global IOM, XT Models
Section 1: Model Nomenclature and AHRI Data
Ground Loop Heat Pump
Ground Water Heat Pump
Note:
Rated in accordance with ISO Standard 13256-1 which includes Pump Penalties.
Heating capacities based on 68.0°F DB, 59.0°F WB entering air temperature.
Cooling capacities based on 80.6°F DB, 66.2°F WB entering air temperature.
Entering water temperatures: 50°F heating / 59°F cooling.
Note:
Rated in accordance with ISO Standard 13256-1 which includes Pump Penalties.
Heating capacities based on 68.0°F DB, 59.0°F WB entering air temperature.
Cooling capacities based on 80.6°F DB, 66.2°F WB entering air temperature.
Entering water temperatures Full Load: 32°F heating / 77°F cooling.
Entering water temperatures Part Load: 41°F heating / 68°F cooling.
AHRI Performance Data
Full Load 19,800 4.3 27,200 20.3
Part Load 16,600 4.8 21,400 29.1
Full Load 29,200 4.2 38,900 18.3
Part Load 23,200 4.6 29,900 27.0
Full Load 38,200 3.9 49,000 17.1
Part Load 29,700 4.3 37,400 24.1
Full Load 47,700 3.7 63,000 17.8
Part Load 38,600 4.3 49,000 24.9
Full Load 55,900 3.6 71,100 17.1
Part Load 46,700 4.1 57,500 23.0
Btu/hr COP Btu/hr EER
FullLoad 24,600 5.3 29,600 26.9
PartLoad 18,200 5.5 22,400 34.0
FullLoad 35,700 4.9 40,900 23.4
PartLoad 24,800 5.3 30,400 32.8
FullLoad 47,700 4.5 53,600 22.5
PartLoad 34,000 4.9 39,800 29.6
FullLoad 60,000 4.5 67,700 22.4
PartLoad 43,300 4.8 50,800 29.8
FullLoad 70,300 4.3 75,600 21.1
PartLoad 52,800 4.6 59,200 26.9
Model Nomenclature Decoder