EnGenius EP800 - Answering a Call

EnGenius EP800
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DocNo.FM0805issueAPage6
4.ANSWERINGACALL
Thetelephonewillringwhenacallexists.Iftherearemultiplehandsets,thefirstpersontoanswerwillgetthecall,allotherphones
willstopringing.Analarmmessageintheearpiecewillannouncethecallerbeforeyouspeaktothem.
ANSWERINGACALL:
1.WhenthehandsetringspresstheTALKkey
2.Listentothealarmmessageintheearpiece
3.Pressthekeyafterthemessagetoopenspeech
4.Speaktotheresident,stopspeakingtolisten
5.Pressthe#keytoendthecall
6.PresstheENDkeytocleartheconnection
______________________________________________________________________________________________________________
NORMALCALLTYPES:
Analarmcallinitiatedbyaresidentwillnormallybefromtheintercomunit,aceilingpullcordorapersonalpendant.
Thefollowingmessageswillbeheard;


intercomalarmflat1 ifthecallwasmadefromtheintercomunitinflat1
pullcordalarmflat1 ifthecallwasmadefromaceilingpullcordinflat1
pendantalarmflat1 ifthecallwasmadefromapersonalpendantallocatedtoflat1
______________________________________________________________________________________________________________
AUTOMATICCALLTYPES:
Analarmcalltriggeredautomaticallymaybefromasmokedetector,aPIRmovementdetectororanotherenvironmentaldevice.
TheAdventxtmonitorsitselfforfaultsandthesearealsoreported,seeexamplesbelow;
smokealarmflat1thesmokealarmhasdetectedafireinflat1

intruderalarmflat1 thePIRhasdetectedanintruderinflat1
faultalarmflat1 there’safaultwiththeintercominflat1
opencircuitalarmflat1 there’sawiringfaultonaceilingpullcordinflat1
systemmainsfailthesystemmainssupplyhasfailed

systembatterylowthesystembatterystandbyisrunninglow

systemmainsrestoredthemainssupplyisrestored
systemBTlinefaultthere’safaultwiththetelephoneline

systemBTlinerestoredthetelephonelineisrestored

systemfuseblownthesystemhasblownafuse
TheREDFAULTSEXISTlightwillbeilluminatedontheStatusModuleasareminderthataproblemrequiresattention.
Thefaultscanbelistedbyenteringaspecialcodeviathecordlesshandset,seeSection13ofthismanual.
______________________________________________________________________________________________________________
Ifyougeta“SystemFuseBlown”messagenoneoftheintercomunitswillbeabletomakeanemergency call.
ContactyourServiceEngineerimmediately.