10.SELECTINGTHEOPERATINGMODE
TheAdventxtwardencallsystemcanreportcallsinthreedifferentways;
1. ONSITEMODE‐toanonsitecarerviaacordlesshandset

2. LOCALOFFSITEMODE‐toamobilecarerviaamobiletelephone
3. REMOTEOFFSITEMODE‐to24hourcontrolcentreviathetelephoneline
TheoperatingmodeisselectedviaakeyswitchontheStatusModule,byentering
specialcodesonthecordlesshandsetorfromtheoptionalManager’sPanel.
______________________________________________________________________________________________________________
MODESELECTIONUSINGTHESTATUSMODULE:
TheStatusModuleisusuallywallmountedintheManagersoffice.

______________________________________________________________________________________________________________
MODESELECTIONUSINGTHECORDLESSHANDSET:
1.PresstheTALKkeyandenter81
2.WaitfortheReadypromptintheearpiece
3.Enterthecode1004followedbythekey
4.Thecurrentoperatingmodewillbeannounced
5.WaitfortheReadypromptintheearpiece
6.PresstheENDkeytomaintainthecurrentoperatingmodeor
Enteroneofthefollowingcodestoselectanewoperatingmode;
1005forOnsiteMode,1006forLocalOffsiteModeor1007forRemoteOffsiteMode
7.Pressthekeyandthenewoperatingmodewillbeannounced
8.PresstheENDkeytocleartheconnection
______________________________________________________________________________________________________________
MODESELECTIONUSINGTHEMANAGER’SPANEL:
1.TouchtheSystemPaneltabalongthetopofthescreen
2.ThecurrentoperatingmodewillbeGREEN
3.Touchtherequiredoperatingmodebuttononthescreen
4.YouwillbepromptedforaPasswordtochangetheoperatingmode
5.EnterthePassword(default:1234)
thentouchtheLogonbutton
6.ThenewoperatingmodewillbeGREEN
______________________________________________________________________________________________________________
Ifthesystemisoperatinginonsitemodeandanalarmcallremainsunansweredforapresettime(6minutes)the
callwillautomaticallyswitchtolocaloffsitemodeandreportthecalltoamobilewarden.Ifthecallstillgoes
unansweredthenremoteoffsitemodewillbe
selectedandthecallwillgotoa24hourcontrolcentre.
Itisnotpossibletoselectlocaloffsiteorremoteoffsitemodeifatelephonelinefaultexists.Ifthesystemis
operatingineitherofthesemodeswhenatelephonelinefaultdevelopsthenthesystemwillreportcallstothe
onsitemanager.Callswillgobacktotheselected
offsitemodeassoonasthefaultclears.
Atelephonelinefaultisreportedonthecordlesshandset,theStatusModuleandaBTlinefaultbeacon(iffitted).
1.Turnthekeyswitchtoselectthedesiredoperatingmode.
2.ChecktherelevantYELLOWOPERATINGMODElightislit.
3.Removethekeyfromtheswitch.
Theoperatingmodecannotbechangedwhen theGREENCALLINPROGRESSlightislit.
Waituntilthecallhasendedbeforeturningthekey.
TheREDFAULTSEXISTlightwillbelitiffaults arestoredinthesystemmemory.
Seesection13forhowtocheckthefaultmemory.
Thetime&dateofallsystemeventscanberecordedonanoptionalprinter.
Onsite
Mode
Optional
Printer