Main Menu
View/Print Job Logs
Print Job Key Setup
Configuration Report
Passcode Protection
Contractor Name
Alarm Setpoints
Date & Time
Print/Log Rates
Response Rate
Pressure Units
Zero Calibrate
Aux Alarm Setup
Display Setup
Modem Setup
Starting A New Job
1. PRINT JOB for printout of current job.
2. START JOB to name new job & end previous job.
3. Check Date & Time, set if needed.
4. Check Alarm 1 & 2 setpoints (operating window), adjust if needed.
5. Connect pressure tubing to #1 inlet.
Unit will display WAITING FOR PRESSURE and STATUS LED will flash
green until pressure reaches operating window. Once reached, displays
NORMAL and STATUS LED shows steady green, unit begins printing &
logging of pressure readings.
Example Editing Session
1. MENU to go to main menu.
2. Scroll highlight to ALARM
SETPOINTS using ▲/▼.
3. SELECT to go to the settings
screen.
4. Alarm 1 setting can now be
increased or decreased by us-
ing ▲/▼.
5. Once desired value is reached,
press
/
to highlight Alarm
2 setting. Pointer to left of Alarm
1 will move to Alarm 2 and info
box text will show Alarm 2 info.
6. Use ▲/▼ to adjust value of
Alarm 2 setting.
7. SAVE updated settings for
Alarm 1 & 2 by pressing SAVE.
SAVE'ed settings are printed &
logged to memory.
or
EXIT to return to main menu
without saving . You can exit
editing session at any time.
• use SELECT to
view or change
settings of main
menu functions •
Help Menu
How To Navigate
Current Status
Audible Alarm Silence
Loading Paper
? Will Not Print
? Pressure Stuck
? Paper Jam
? False Alarms
? Tech Support
• detailed HELP
information is
always available by
pressing HELP •
Monitor Screen
Main Menu
Alarm Setpoint Screen
Omniguard 4 Quick Reference
"WC
Alarm 1: -0.025"
Alarm 2: -0.100"
N O R M A L
-0.058
VIEW/PRINT JOB LOGS
PRINT JOB KEY SETUP
CONFIGURATION REPORT
PASSCODE PROTECTION
CONTRACTOR NAME
SELECT EXIT HELP MAIN MENU
Alarms 1 & 2 are upper
and lower setpoint.
Defaults are -0.025 and...
-0.025
ALARM 1:
ALARM 2: -0.100
SELECT SAVE EXIT HELP
0
-0.20
ALARM SETPOINTS
-Alarm 1 is upper setpoint.
Alarm 2 is lower setpoint.
-Normal operating window
is area between Alarm 1
EXIT HELP
HELP INFO
N O R M A L
058
-
.
Pressure Only Monitor Screen
Alarm Setpoint Help Screen