Technical Data
Technical Considerations
Be sure to verify the voltage and current specifications of your PV module match those of the
microinverter. For more information, refer to our module compatibility calculator.
WARNING: Risk of equipment damage. You must match the DC operating voltage
range of the PV module with the allowable input voltage range of the Enphase
Microinverter.
WARNING: Risk of equipment damage. The maximum open circuit voltage of the PV
module must not exceed the specified maximum input voltage of the Enphase
Microinverter.
The output voltage and current of the PV module depends on the quantity, size and temperature of the
PV cells, as well as the insolation on each cell. The highest PV module output voltage occurs when the
temperature of the cells is the lowest and the PV module is at open circuit (not operating). The maximum
short circuit current rating of the PV module must be equal to or less than the maximum input DC short
circuit current rating of the microinverter.