How the Microinverter Works
The Enphase Microinverter maximises energy production from your photovoltaic (PV) array. Each
Enphase Microinverter is individually connected to one PV module in your array. This configuration
means that an individual Maximum Peak Power Point Tracker (MPPT) controls each PV module. This
ensures that the maximum power available from each PV module is exported to the electricity network
regardless of the performance of the other PV modules in the array. That is, although individual PV
modules in the array may be affected by shading, soiling, orientation, or PV module mismatch, the
Enphase Microinverter ensures top performance for its associated PV module. The result is maximum
energy production from your PV system.
System Monitoring
Once you install the Envoy Communications Gateway and provide an Ethernet connection to your
broadband router or modem, the Enphase Microinverters automatically begin reporting to the Enphase
Enlighten web server. The Enlighten software presents current and historical system performance trends,
and it informs you of PV system status.
Optimal Reliability
Microinverter systems are inherently more reliable than traditional inverters. The distributed nature of a
microinverter system ensures that there is no single point of system failure in the PV system. Enphase
Microinverters are designed to operate at full power at ambient temperatures as high as 65 C (150 F).
The microinverter housing is designed for outdoor installation and complies with the IP67 regulation:
IP67 protective factor definition: Entirely protected against the effects of dust and
immersion.
NOTE: To ensure optimal reliability and to meet warranty requirements, the Enphase Microinverter must be
installed according to the instructions in this manual.
Ease of Design
PV systems using Enphase Microinverters are very simple to design and install. You will not need string
calculations, and you can install individual PV modules in any combination of PV module quantity, type,
age and orientation. You won’t need to install cumbersome traditional inverters. Each microinverter
quickly mounts on the mounting rail, directly beneath each PV module. Low voltage DC wires connect
from the PV module directly to the co-located microinverter, eliminating the risk of personnel exposure to
dangerously high DC voltage.

Table of Contents

Other manuals for enphase M250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the enphase M250 and is the answer not in the manual?

enphase M250 Specifications

General IconGeneral
ModelM250
ManufacturerEnphase Energy
Efficiency96.5%
Output Voltage240 V
Operating Temperature Range-40°C to +65°C
Maximum Output Current1.04 A
CEC Efficiency96.0%
Start-up Voltage22 V
Output Frequency60 Hz
Enclosure RatingIP67
Weight1.6 kg