The Proame 2 IFC (Figure 7) connects directly to the gas valve, stepper motor, pilot and covection fan with a wiring
harness. The IFC is mainly powered by 120 VAC but can also run off a battery backup four (4) AA type batteries for
shorter periods of time. The IFC accepts commands via radio frequency from the Transmitter to operate the appliance
in accordance with the particular Proame 2 system conguration. The IFC has a red reset button at the front right
corner that is used is to synchronize the Transmitter when using the for the rst time, or after the batteries have been
replaced.
Figure 6: Proame 2 Transmitter LCD Screen.
Figure 7: Integrated Fireplace Controller
CPI Mode
Operating Instructions
integRateD fiRepLace contRoLLeR (ifc):
Reset Button
10