Instructions for use Epec 4W30 27
(C) Epec Oy Seinäjoki Finland
The feed method is selected as follows:
1. Press Enter and adjust the desired value with the programming
wheel.
2. Accept adjustment with Enter or leave previous value in force
with Cancel.
The values of the feed methods are:
0 = manual feed
1 = automatic feed (feed by preselection)
2 = continuous feed
7.3 Saw Max Pulses (3)
Parameter is used to set the maximum amount of pulses coming
from the saw position indicator.
If the saw does not saw big trees sufficiently, this parameter should
be increased.
Setting range 0 – 255.
NOTE!
When you have changed the value you must then open and close the
grapple. The new value becomes valid after doing this.
7.4 Saw Min Pulses (4)
Parameter is used to set how much pulses there must at least come
from the saw, before the saw returns into the casing. There must
always come at least this amount of pulses from the saw.
If the saw does not saw small trees sufficiently, this parameter should
be increased.
Setting range 0 – 255.
NOTE!
When you have changed the value you must then open and close the
grapple. The new value becomes valid after doing this.
7.5 Basic Flow (K5)
This is used to adjust the output of the hydraulic pump during
different motions. Such motions are for instance grapple open and
grapple closed, tilt up and turn left and right.
Demands a proportional pump.
Setting range 0 – 100 %