7.6 Sawing Output (K6)
− This is used to adjust the pump output during sawing.
− If the output is too small, sawing is slow or does not succeed.
− If the output is too high, the motor is strongly loaded.
− Demands a proportional pump.
− Setting range 0 – 100 %
7.7 Low Speed Rate (K7)
− The minimum rate setting is used to set a suitable low speed feed
rate (so right length can be found fast).
− If a pump with adjustable volume and a proportional valve are used,
this setting controls directly the pump output when low speed is used.
− Demands a proportional pump.
− Setting range 0 – 100 %
7.8 Feed Rate (K8)
− This parameter is used to set a suitable pump angle / output during
the feed, i.e. the pump output can be limited.
− If the output is too small, the feed is slow.
− Feed rate should be adjusted first to a lower value and then it should
be increased, until the speed does not increase any more.
− The machine must have reached running temperature.
− Demands a proportional pump.
− Setting range 0 – 100 %
7.9 Overrunning Method (9)
− Overrunning means feed past the selected length and then reversing
to the selected length. Overrunning can be used for example in
delimbing.
− The overrunning method is set as follows:
1. Press Enter. Then the shading is transferred to the value.
2. Rotate the programming wheel until you get the desired value.
3. Press Enter, if you accept the change, or Cancel, if you do not
want to make the change.
− 0 = overrunning not in use, 1 = overrunning in use.