Instructions for use Epec 4W30 29
(C) Epec Oy Seinäjoki Finland
7.10 Transfer of the Diameter Curve (Thin end and thick
end) (10 – 11)
The diameter curve can be inclined upwards or downwards at the
minimum end and at the maximum end.
This inclination is necessary, when a check of the volume
measurement has revealed a deviation. Detailed information is found
in enclosure "2. Diameter calibration".
Inclining range is between -127 and 128.
7.11 Setting of Date and Time (12 – 15)
Date and time are set as follows:
1. Select the setting you want to change: year, month, day or
time.
2. Press Enter and adjust the desired value with the programming
wheel.
3. Accept adjustment with Enter or leave previous value in force
with Cancel.
7.12 Advance Distance of the Diameter Measurement (16)
The advance distance of the diameter measurement is the distance
of the diameter measurement position from the saw position. This
information is necessary for the volume calculation and for stopping
at the diameter limits.
Setting range 0 – 255 cm.
NOTE!
Measuring equipment displays the diameter of the sawing position.
7.13 Language (17)
This parameter is used to set the language used:
Fin = Finnish, S = Swedish, Gb = English, Deu = German.
7.14 Diameter in Use (18)
Setting is used to operate the measuring equipment without volume
calculation and diameter.
0 = not in use, 1 = in use.