7.27 Pump Release Delay (K35)
The setting is used to set the time that the pump is on after the other
outputs have been switched off.
Setting range 0 – 3 s.
7.28 Proportional Pump in Use (K36)
This is used to inform the equipment, whether a proportional pump is
in use.
If no proportional pump is in use, the settings of the pump angle have
no influence and the parameters K5 - K8 are not visible.
0 = not in use, 1 = in use.
7.29 Length of Search Pulse (K37)
Setting of the length of the search pulse.
Is automatically regulated to get the tree to move 2 cm with one
pulse.
Because of the automatic regulation this value should not be adjusted
manually when the machine is searching with search pulses. The
suitable pre-set value is 10.
7.30 Low Speed Feeding Pulse (K38)
Setting of the low speed feeding pulse. No influence, if a proportional
pump is in use.
Is automatically regulated to get the tree to move 2 cm with one
pulse.
Because of the automatic regulation this value should not be adjusted
when the machine is searching with low speed. The suitable pre-set
value is 10.
7.31 Slip Prevention (K39)
This time is used to regulate how long the feed outputs are kept on, if
there comes no length pulses.
Zero indicates that slip prevention is not in use.
Setting range 0 – 0.5 s. If the value is too small, the feed will not
work, since the machine thinks too early that the tracks slip.