33
Operator's instructions
4. Controls
Menu views
Settings submenus
NOTE: Settings in the submenus require login level OP.
The setting main menu contains the following submenus:
Under Drill Control System, active functions are visible
Under RPCF (Rotation Pressure Control Feed), the following settings can be made:
n
Enabled
: If the setting is changed to NO, then the RPCF function is deactivated.
n
Start (bar):
The setting for rotation pressure at which the drill feed pressure starts to
drop.
n
Stop (bar):
The setting for rotation pressure at which the drill feed pressure should be
Y103 min. At higher rotation pressure the feed pressure does not drop further.
n
Y103 min (mA):
Minimum setting for current for Y103 that activates the valve.
n
(Y103 low):
The setting in brackets is collaring-feed pressure. It cannot be adjusted
here,
but is shown as comparison with the minimum setting for feed pressure.
Under ECL (Electric Controlled Lubrication), the following settings can be made:
n
Pulses/minute
: Pulses per minute
n
Extended time
: Total time for pump cycle.