MMS6110Directionforuse
TechnicalData Page39
6.
TECHNICALDATA
Onlyspecificationswithtolerancesareguaranteed.Datawithouttolerancesorwithouterror
limitsareonlyforinformationpurposesandarenotguaranteed.Technicalchanges,espe-
ciallyofthesoftware,aresubjecttoalterations.
Ifnotstatedotherwise,thespecificationsinthefollowingchapterarevalidforchannel1and
channel2.
6.1 Signalconditioning
Twoseparatesignalinputsforchannel1andchannel2withthesignalcondition-
ingdecoupledfromeachother.
Signalinputs
Differentialinputs,non-reactive,open-circuitandshort-circuitproof.
channel1 z8:SENS1H(+); z10:SENS1L(-Signal)
channel2 d8:SENS2H(+); d10:SENS2L(-Signal)
Nominalinputsignalrange -1,0...-22,16V
Limitrange 0...-30VDC
Inputresistance
>100k
Sensorsignaloutputs
SMBfrontsockets,decoupled,open-circuitandshort-circuitproof,non-reactive
channel1-SENS1 SMBK1
channel2-SENS2 SMBK2
Signaloutput -1...-24V;signal1:1tosensorinputsignal
Accuracy ±1
%off.s.d.
Frequencyrange 0...16kHz(-3dB)±20
%
permissibleload
>100k
Internalresistance
1k
Dynamicoutputs
Thedynamicpartofthesensorsignalisoutputasscaledvalue.
channel1-AC1/channel2-AC2 z14/z16open-circuitandshort-circuitproof,
non-reactive
Nominalrange 0...20Vpp
Measuringrange accordingtothemeasuringrangeconfigured
forthecharacteristicalvalue,min.400mVpp,
max.8000mVpp
Accuracy ±1%off.s.d.
Frequencyrange 0,1Hz...16kHz(-3dB),±20%
permissibleload
>10k