4.2.3 Removing the SUB Board
1. Remove the Upper Housing. See Section 4.2.2 on page 40.
2. Remove the C.B.P. M3 x 8 screw that secure the SUB Board Unit,
and remove it.
Figure 4-11. Removing the SUB Board Unit
3. Disconnect the Panel Board Connector CN1 and the SUB Board
Connector CN2 connected to the SUB Board.
Figure 4-12. Removing the SUB Board Unit (1)
4. Remove the SUB Board from the SUB Board Holder.
Figure 4-13. Removing the SUB Board Unit (2)
SUB Board Unit
C.B.P. 3x8 (7±1 kgf.cm)
Panel Board Connector
(CN1)
SUB Board
SUB Board Connector
(CN2)
When installing the SUB Board to the Sub Board
Holder, match the notch and tab as shown in Figure
4-13.
Route the SUB Board Connector cable through the
notches on the Lower Housing as shown below.
Figure 4-14. Routing the SUB Board Connector Cable
SUB Board
SUB Board Holder
Notch and Dowel
Notches