<Head Voltage Value Setting>
Head Rank (0-14) : n
6.
Change the value by pressing the ↑ and ↓ keys. If the current value is the same as the value
printed on the printhead, press Enter to write the head rank data to the EEPROM. The
program next lets you write the normal dot and micro dot head voltage data.
7.
Use the ↑ and ↓ keys to change the normal dot / micro dot head voltage values, in the same
way as was described in step 6.
<Head Voltage Value Setting>
Head Rank (0-14) : n
Normal Dot : n
Micro Dot : n
Go: <ENTER> Again: <SPACE> n
8. Press ENTER to exit the menu, or press SPACE to continue making settings.
CAUTION
❒ The values are not permanently stored in EEPROM until the printer is turned off. Turn
off the printer immediately after adjustment.
❒ Reset protect counter B using the adjustment program to make the printer perform the
initial ink charge operation before sending the unit back to the customer.
9. The menu below appears on the display. If you want to end the program, press 5.
Stylus 1500 <********> Customer Data <********> 95/**/**
( Customer Data Input ) .... 1
( Adjustment ) .... 2
( END ) .... 5
SELECT MENU
■
10. Turn off the printer.
Adjustments
4-10 EPSON Stylus 1500 Service Manual