Release Sensor Removal
1. Remove the upper housing. (See page 3-7.)
2. Disconnect the cable from the connector on the sensor.
3. Remove the sensor from the left frame. (Insert tweezers to release the hook securing the sensor
to the left frame. Then pull the sensor off, as shown in the figure below.)
Carriage Home Position (HP) Sensor Removal
1. Remove the upper housing. (See page 3-7.)
2. Disconnect the cable from the connector on the sensor.
3. Remove the sensor from the paper eject frame. (Insert tweezers to release the hooks securing
the sensor to the paper eject frame. Then pull the sensor off, as shown in the figure below.)
Release Sensor
Tweezers
Release Sensor Cable
Hook for Sensor
Figure 3-11. Removing the Release Sensor
HP Sensor
Tweezers
Paper Eject Frame
HP Sensor Cable
Figure 3-12. Removing the HP Sensor
Disassembly and Assembly
EPSON Stylus 1500 Service Manual 3-15

Table of Contents