7. Refer to the pattern and input a value from –12 to 12 to align both black and magenta lines (or
to bring F within 0 ± 0.035 mm), as shown in the following flowchart.
8. Press ENTER to exit the setting mode, or press SPACE to continue making settings.
CAUTION
The values are not permanently stored in EEPROM until the printer is turned off. Turn
off the printer immediately after adjustment.
Reset protect counter B using the adjustment program to make the printer perform the
initial ink charge operation before sending the unit back to the customer.
9. The menu below appears on the display. To end the program, press 5.
Stylus 1500 <********> Customer Data <********> 95/**/**
( Customer Data Input ) .... 1
( Adjustment ) .... 2
( END ) .... 5
SELECT MENU
10. Turn off the printer.
F
START
Choose " Head Gap Adj." to enter
the head gap adjustment
Select the resolution
Is the head gap OK ?
To main menu
Which direction is
the pattern ?
Input -1 value and
ENTER key
Input +1 value and
ENTER key
Press ENTER key
Are all resolutions
OK ?
YES
NO
YES
NO
Press ENTER key
Figure 4-18. Head Gap Adjustment Flowchart
Adjustments