EPSON Stylus Photo 1390/1400/1410 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 127
4. While pressing the Guide Pin on the PF Encoder Sensor Holder using tweezers,
slide the Holder upwards to release the three Tabs, and remove the PF Encoder
Sensor Holder.
Figure 4-144. Removing the PF Encoder Sensor Holder
Make sure that the PF Scale is in the slit on the PF Encoder Sensor.
Figure 4-145. Reinstalling the PF Encoder Sensor Holder
Tabs
Guide Pin
PF Encoder Sensor
PF Scale
Slit