EasyManua.ls Logo

Epson Stylus Photo 1390 - 4.2.8.3 CR Encoder Sensor Board; 4.2.8.4 PF Encoder Sensor Holder

Epson Stylus Photo 1390
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EPSON Stylus Photo 1390/1400/1410 Revision B
DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 126
4.2.8.3 CR Encoder Sensor Board
1. Remove the Carriage Unit. See section 4.2.6.5 on page 98.
2. Remove the two C.B.P. 2.6x5 screws that secure the CR Encoder Sensor Board.
3. Disconnect the FFC of PW Sensor from the Connector of the CR Encoder Sensor
Board, and remove the CR Encoder Sensor Board.
Figure 4-142. Removing the CR Encoder Sensor Board
4.2.8.4 PF Encoder Sensor Holder
1. Remove the Upper Housing.
For Stylus Photo 1400/1410: See section 4.2.1.4 on page 80.
For Stylus Photo 1390: See section 4.3.1 on page 128.
2. Disconnect the FFC from the PF Encoder Sensor Board.
3. Remove the C.B.S. M3 x 8 screw that secures the PF Encoder Sensor Holder.
Figure 4-143. Removing the FFC and the Screw that Secures
the PF Encoder Sensor Holder
CR Encoder
Sensor Board
13) C.B.P. 2.6x5
(3±0.5 kgf.cm)
FFC
Connector
PF Encoder Sensor Holder
5) C.B.S. 3x8
(6±1 kgf.cm)
Connector
FFC

Table of Contents