EPSON Stylus Photo 1390/1400/1410 Revision B
TROUBLESHOOTING Overview 45
At operation Though paper is fed from the
ASF Assy, it stops near the PE
Sensor Lever.
PE Sensor 1. Check that the Connector cable of the PE Sensor is securely
connected to the PE Sensor and Relay Board Connector CN2.
1. Connect the Connector cable of the PE Sensor
to the PE Sensor and Relay Board Connector
CN2.
2. Check that the Sensor Holder is mounted to the Mechanical
frame correctly.
2. Install the Sensor Holder correctly.
3. Move the Detection Lever manually as when the paper passes,
and check that the Detection Lever returns to the original
position automatically by the Torsion Spring when released.
Refer to the above photo.
3. Replace the PE Sensor Holder Unit with a new
one.
4. Using a tester, check that the PE Sensor is normal.
Paper absent: 2.4V or more
Paper present: 0.4V or less
4. Replace the PE Sensor Holder Unit with a new
one.
Table 3-4. Troubleshooting of Paper Out Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
CN2
PW Sensor Connector
Sensor Holder
Detection Lever