TROUBLESHOOTING Overview 56
At power-on At power-on, the Pump Motor
does not operate at all.
Relay Connector
Cable
(for Pump
Motor)
1. Check that the Relay Connector Cable is connected to the Main
Board Connector CN8.
1. Connect the Relay Connector Cable to the
Main Board Connector CN8.
2. Check the Relay Connector Cable for damages. 2. Replace the Relay Connector Cable with a new
one.
While the power-on sequence is
being executed, Fatal error is
displayed.
APG Sensor 1. Check that the APG Sensor Connector cables are connected to
the APG Sensors and Relay Board Connector CN4 and CN5.
1. Connect the APG Sensor Connector cables to
the APG Sensors and Relay Board Connector
CN4 and CN5.
2. Check the APG Sensors for damages. 2. Replace the APG Sensors with new ones.
Table 3-11. Troubleshooting of Fatal Error