EPSON Stylus Photo 1390/1400/1410 Revision B
TROUBLESHOOTING Overview 57
At power-on While the power-on sequence is
being executed, Fatal error is
displayed.
ASF Motor 1. Check that the Connector cable of the ASF Motor is connected to
the Relay Connector.
1. Connect the Connector cable of the ASF Motor
to the Relay Connector.
2. Using a tester, check the resistance value of the ASF Motor.
Value of resistance: 7.0 ± 10%
2. If the resistance value is abnormal, replace the
ASF Motor with a new one.
3. Check the ASF Motor connector cable for damages. 3. Replace the ASF Motor with a new one.
Relay Connector
Cable
(for the ASF
Motor)
1. Check that the Relay Connector Cable is connected to the Main
Board Connector CN13.
1. Connect the Relay Connector Cable to the
Main Board Connector CN13.
2. Check the Relay Connector Cable for damages. 2. Replace the Relay Connector Cable with a new
one.
Table 3-11. Troubleshooting of Fatal Error
Occurrence
Timing
Phenomenon Detail
Faulty Part/
Part Name
Check Point Remedy
Relay Connector
ASF Motor
CN13

Table of Contents