DISASSEMBLY AND ASSEMBLY Disassembly/Assembly Procedures 93
5. Release the coil section of Torsion Spring 24.7 from the tab on the Left CR Shaft
Mounting Plate with tweezers.
Figure 4-42. Removing the Torsion Spring 24.7 (1)
6. Remove Torsion Spring 24.7 from the CR Scale following the next steps:
6-1. Bring the coil section to an upright position.
6-2. Push downwards to release foot 1 from the cutout on the Left CR Shaft
Mounting Plate.
6-3. Turn the coil section counterclockwise.
6-4. Remove Torsion Spring 24.7 from the hole on the CR Scale.
Figure 4-43. Removing the Torsion Spring 24.7 (2)
7. Turn the CR Scale 90°, and remove it from the tab on the Left CR Shaft Mounting
Plate.
Figure 4-44. Removing the CR Scale
Left CR Shaft
Mounting Plate
Torsion Spring 24.7
Tab
Step 6-1
Step 6-2
Step 6-3
Foot 1
Cutout
Tab