EPSON Stylus PHOTO 895/785EPX Revision A
Disassembly and Assembly Preview monitor disassembly procedure 113
4.3.3 Panel unit removal
1. Detach the back case (Refer to 4.3.1.)
2. Remove the control board unit. (Refer to 4.3.2)
3. Remove two screws securing the panel assembly and then remove the panel
assembly.
Figure 4-79. Panel assembly removal
4. Remove the hook from shield board and detach the shield plate and panel unit.
Figure 4-80. Panel unit removal
Panel assembly
Screws
Hook
Shield plate
Panel unit
A D J U S T M E N T
R E Q U I R E D
When the panel unit is replaced, make sure to adjust as follows:
Brightness adjustment
Image pattern inspection