EPSON Stylus PHOTO 895/785EPX Revision A
Disassembly and Assembly Disassembly 93
4.2.11 Ink system unit removal (Cap & Pump unit )
1. Remove the Housing from the printer. (Refer to Section 4.2.1 "Housing Removal")
2. Remove the Waste drain ink pad from the printer. (Refer to Section 4.2.6 "Waste
drain ink pad unit removal")
3. Remove one screw (C.B.S (P4) 3x6 F/ZN) and detach the pump unit cover.
Figure 4-40. Pump unit cover removal
Tor
Make sure that the HP or PE sensor cable is placed to the
suitable groove on the LD roller shaft holder.
Figure 4-39. Sensor cable placing position
Make sure that the each sensor lever turn back smoothly by
moving it after the sensor was assembled to the LD roller shaft
holder.
HP sensor cable
PE sensor cable
C.B.S (P4) 3x6 F/ZN